[Skip to main content] [Skip to secondary navigation] [Skip to accesskey list ]

Greenstar Camray System 25/32 Technical data table

Technical data
Title Value
Height (mm) 855
Width (mm) 370
Depth (mm) 600
Weight 117kg
SEDBUK Value/band 94.2%/Band A
Solar compatible Yes
Burner Reillo RDB 2.2
Optional plug-in twin channel digital controls Yes
Minimum diameter flue CF 130mm (can be 100mm when using Worcester flexi-flue kit)
Minimum diameter flue RS 80/125mm (H), 100/150mm (V)
Primary vent 1 1/4 inch BSP
Primary cold feed 3/4 inch BSP
Heating flow and return connections 28mm
Condensate connection 21.5mm
Condensate trap Accessory kit supplied
Oil connection 10mm
Max. primary static head 30m
Min. primary static head 1m
Primary water content 28L
NOx class Class 3, 156mg/kWh
Available pump head 20°C 4.1mH2O
Exhaust flue gas mass flow 51kg/hr
Control thermostat differential 55/81c
Power consumption 265w
Ingress protection rating IP20
Flue reset overheat thermostat (cut out) (°C) 110
Boiler manual reset overheat thermostat (cut out) 105c
Boiler high limit thermostat (cut out) (°C) 95
Max. horizontal flue RS 80/125 (mm) 4,000
Maximum hearth temperature <100c
Maximum vertical flue RS 8,000mm when max. vertical flue RS= 150mm dia.
Power supply 230V, 50Hz