[Skip to main content] [Skip to secondary navigation] [Skip to accesskey list ]

Greenstar Danesmoor 18/25 (discontinued Sept 2011) Technical data table

Technical data
Title Value
Height (mm) 855mm
Width (mm) 370mm
Depth (mm) 600mm
Weight 119kg
SEDBUK Value/band 92.9% Band A
Solar compatible Yes
Minimum diameter flue CF 100mm
Minimum diameter flue RS 80/125mm
Primary vent 1 inch BSP
Primary cold feed 1 inch BSP
Heating flow and return connections 1 inch BSP, 22mm
Condensate connection 21.5mm polypropylene
Oil connection 10mm
Max. primary static head 30 metres
Maximum flow temperature 81°C
Minimum flow temperature 55°C
Min. primary static head 1 metre
Primary water content 24.5 litres
NOx class Class 3, 209mg/kWh
Water side resistance 20°C 57 mbar
Exhaust flue gas mass flow 40kg/hr
Control thermostat differential 5°C
Power consumption 155W
Ingress protection rating IP 20
Flue reset overheat thermostat (cut out) (°C) 110°C
Boiler manual reset overheat thermostat (cut out) 105°C
Boiler high limit thermostat (cut out) (°C) 95°C
Maximum hearth temperature <100°C
Maximum horizontal flue RS 6,000mm
Maximum vertical flue RS 12,000mm
Power supply 230 AC V 50Hz
Output to central heating kW 18-25
Output to central heating (Btu) 61,400-85,300