Greenstar Danesmoor WM 12/18 Technical data table

Technical data
Title Value
Primary water content (litres) 23
Maximum static head (metres) 30
Minimum static head (metres) 1
Exit flue gas mass flow (kg/hr) 29
Fuel line (compression) (mm) 10
Condensate (polypropylene) (mm) 21.5
Electrical power supply voltage (AC V) 230
Frequency (Hz) 50
Maximum power consumption (W) 150
CH flow temperature range (min/max) (°C) 55/81
CH control thermostat differential (°C) 5
Height (mm) 880
Width (mm) 600
Weight (lift) 72.5kg
Depth (mm) 380
Weight 108.5kg (dry)
Appliance protection rating 20
SEDBUK Value/band 92.6%/Band A
Solar compatible Yes
Maximum horizontal flue (125mm Ø) 4,000
Maximum vertical flue (125mm Ø) 6,000
Minimum diameter flue CF 100mm
Minimum diameter flue RS 80/125mm
Primary vent 22mm copper
Primary cold feed 22mm copper
Heating flow and return connections 22 copper
Oil connection 10mm
NOx class Class 1, 160mg/kWh
Water side resistance 20°C 30
Flue reset overheat thermostat (cut out) (°C) 110
Boiler manual reset overheat thermostat (cut out) 105
Boiler high limit thermostat (cut out) (°C) 95
Maximum horizontal flue RS 4,000mm
Maximum vertical flue RS 6,000mm
Output to central heating kW 12-18Kw
Output to central heating (Btu) 40,950-61,400Btu