[Skip to main content] [Skip to secondary navigation] [Skip to accesskey list ]

Greenstar Danesmoor WM 18/25 Technical data table

Technical data
Title Value
Primary water content (litres) 23
Maximum static head (metres) 30
Minimum static head (metres) 1
Exit flue gas mass flow (kg/hr) 40
Fuel line (compression) (mm) 10
CH vent (optional) 22mm copper
CH make-up (cold feed) 22mm copper
Condensate (polypropylene) (mm) 21.5
Electrical power supply voltage (AC V) 230
Frequency (Hz) 50
Maximum power consumption (W) 160
CH flow temperature range (min/max) (°C) 55/81
CH control thermostat differential (°C) 5
Height (mm) 880
Width (mm) 600
Weight (lift) 72.5kg
Depth (mm) 380
Weight 108.5kg (dry)
Appliance protection rating 20
Output to central heating 18-25Kw (61,400-85,300Btu)
Solar compatible Yes
Maximum horizontal flue (125mm Ø) 4,000mm
Maximum vertical flue (125mm Ø) 6000mm
Minimum diameter flue RS 80/125mm
Heating flow and return connections 22mm copper
NOx class Class 1, 160mg/kWh
Water side resistance 20°C 69
Flue reset overheat thermostat (cut out) (°C) 110
Boiler manual reset overheat thermostat (cut out) 105
Boiler high limit thermostat (cut out) (°C) 95

Social media


Home | Find a boiler | Find an installer | Head office contacts | Sitemap | Accessibility |