[Skip to main content] [Skip to secondary navigation] [Skip to accesskey list ]

Greenstore 11 System Technical data table

Technical data
Title Value
Height 1,520mm
Width 600mm
Depth 600mm
Weight 164kg
Emitted/supplied output at 0/45°C 1 9.63 / 2.92
COP 0/35ºC 5 4.6
COP 0/45°C 1 3.29
COP 0/50ºC 5 3.2
Min. flow heating side 0.26l/s
Nominal flow heating side 0.37l/s
Max. pressure available heating side (at nominal flow) 33kPa
Nominal flow of antifreeze mixture to the collector hose 0.57l/s
Max. pressure available to collector hose (at nominal flow) 80kPa
Type of antifreeze Bioethanol-water or Propylene/ethylene glycol/water
Freeze protection temperature -15°C
Max. pressure heating side 2.5bars
Max. pressure on collector hose side 4bars
Max. outgoing temperature to the heating system 65°C
Max. return temp. from heating system 57
Working temperatures on collector hose side -5 to +20°C
Integrated collector hose and heat carrier pump Yes
Power supply 230V 1N~ 50Hz
Additional heat settings 3.0 / 6.0 / 9.0kW
Fuse, 6kW electric heater 2 50AaM
Fuse, 9kW electric heater 2 63AaM
Starting current 34.6A
Compressor Scroll
Type R407c HFC refrigerant 2.4kg
Connection for heat fluid out/in Cu 22mm
Out/in collector hose connection Cu 28mm
Control unit Rego 637W
Sound power level 3 48.3dB(A)
Sound pressure level 4 35.6dB(A)

Technical data notes

  1. Data at 0/45 °C according to the European standard EN 14511. Data applies to a new unit with clean heat exchangers
  2. aM type fuse, D characteristic MCB
  3. Measurement according to EN ISO 3743-2
  4. Calculated values at 1m distance according to EN ISO 11203
  5. According to EN14511

Social media


Home | Find a boiler | Find an installer | Head office contacts | Sitemap | Accessibility |