[Skip to main content] [Skip to secondary navigation] [Skip to accesskey list ]

Greenstore 7 Combi Technical data table

Technical data
Title Value
Height 1,800mm
Width 600mm
Depth 600mm
Weight (empty) 217kg
Weight (full) 442kg
Emitted/supplied output at 0/45°C 1 6.55/2.20
COP 0/35ºC 5 3.9
COP 0/45°C 1 2.97
COP 0/50ºC 5 2.9
Min. flow heating side 0.18L/s
Nominal flow heating side 0.25L/s
Max. pressure available heating side (at nominal flow) 36kPa
Nominal flow of antifreeze mixture to the collector hose 0.38L/s
Max. pressure available to collector hose (at nominal flow) 45kPa
Type of antifreeze Bioethanol-water or Propylene/ethylene glycol/water
Freeze protection temperature -15°C
Max. pressure heating side of heat pump 2.5bars
Max. pressure on collector hose side 4bars
Max. outgoing temperature to the heating system 65°C
Max. return temp. from heating system 57°C
Working temperatures on collector hose side -5 to +20°C
Integrated collector hose and heating system pump Yes
Power supply 230V 1N~ 50Hz
Additional heat settings 3.0 / 6.0 / 9.0kW
Fuse, 6kW electric heater 2 40AaM
Fuse, 9kW electric heater 2 63AaM
Starting current, soft start 23.8A
Compressor Scroll
Type R407c HFC refrigerant 1.4kg
Connection for heat fluid out/in Cu 22mm
Out/in collector hose connection Cu 28mm
Intergrated hot water cylinder with double shell Stainless steel
Volume of integrated hot water cylinder 185L
Primary water volume 40L
Control unit Rego 637W
Ambient temperature - indoor use +10 to +30°C
Max. relative humidity 60%rH
Sound power level 3 50.1dB(A)
Sound pressure level 4 37.4dB(A)

Technical data notes

  1. Data at 0/45 °C according to the European standard EN 14511. Data applies to a new unit with clean heat exchangers
  2. aM type fuse, D characteristic MCB
  3. Measurement according to EN ISO 3743-2
  4. Calculated values at 1m distance according to EN ISO 11203
  5. According to EN14511

Social media