[Skip to main content] [Skip to secondary navigation] [Skip to accesskey list ]

Greenstore 7 System Technical data table

Technical data
Title Value
Height 1,520mm
Width 600mm
Depth 600mm
Weight 153kg
Emitted/supplied output at 0/45°C 1 6.55/2.20
COP 0/35ºC 5 3.9
COP 0/45°C 1 2.97
COP 0/50ºC 5 2.9
Min. flow heating side 0.18l/s
Nominal flow heating side 0.25l/s
Max. pressure available heating side (at nominal flow) 36kPa
Nominal flow of antifreeze mixture to the collector hose 0.38l/s
Max. pressure available to collector hose (at nominal flow) 45kPa
Type of antifreeze Bioethanol-water or Propylene/ethylene glycol/water
Freeze protection temperature -15°C
Max. pressure heating side 2.5bars
Max. pressure on collector hose side 4bars
Max. outgoing temperature to the heating system 65°C
Max. return temp. from heating system 57
Working temperatures on collector hose side -5 to +20°C
Integrated collector hose and heat carrier pump Yes
Power supply 230V 1N~ 50Hz
Additional heat settings 3.0 / 6.0 / 9.0kW
Fuse, 6kW electric heater 2 40AaM
Fuse, 9kW electric heater 2 63AaM
Starting current 23.8A
Compressor Scroll
Type R407c HFC refrigerant 1.4kg
Connection for heat fluid out/in Cu 22mm
Out/in collector hose connection Cu 28mm
Control unit Rego 637W
Sound power level 3 50.1dB(A)
Sound pressure level 4 37.4dB(A)

Technical data notes

  1. Data at 0/45 °C according to the European standard EN 14511. Data applies to a new unit with clean heat exchangers
  2. aM type fuse, D characteristic MCB
  3. Measurement according to EN ISO 3743-2
  4. Calculated values at 1m distance according to EN ISO 11203
  5. According to EN14511

Social media