Installation requirements
Installation of the Greenstar regular boiler range must be in accordance with the relevant requirements of the Gas Safety (Installation Use) Regulations (as amended), current IEE Wiring Regulations, local Building Regulations, Building Standards (Scotland) (Consolidation) regulations and bylaws of the local Water company and Health and Safety Document No. 635 (Electricity at Work Regulations 1989). It should be in accordance with the relevant recommendations of the following British Standards:
BS 6798; BS 5449; BS 5546:1; BS 5440:1; BS 5440:2; BS 6891.
Gas Safety (Installation and Use) Regulations. All gas appliances must be installed by a Gas Safe registered person in accordance with the above regulations. Failure to install appliances correctly could lead to prosecution.
The manufacturers notes must not be taken in any way as overriding statutory regulations.
It is important with an aluminium heat exchanger that the pH level of the water does not exceed 8. Levels in excess of this could be detrimental to the heat exchanger.
The use of a suitable inhibitor will provide a resistance to this. Contact Sentinel (Tel:0800 3894670) or Fernox (Tel: 01799 521 133) for further details.