[Skip to main content] [Skip to secondary navigation] [Skip to accesskey list ]

Greenstar 12Ri

Man demonstrating Greenstar Ri boiler to woman
Greenstar Ri boiler

Description

Which? Best Buy logoThe Greenstar Ri regular boilers are the smallest of our condensing boilers - they can even be installed within a standard kitchen cabinet.

These boilers are available in 4 different outputs which means that there’s one to suit small, medium and larger properties. The Greenstar Ri Regular boilers are used with a heating system that includes stored hot water in a cylinder.

The Greenstar Ri boilers have a fascia-mounted heating temperature control knob and neon operational status indicator.

For further peace of mind, every boiler in Worcester’s Greenstar gas and LPG condensing boiler range has been awarded a Which? Best Buy accreditation.

10 year guarantee on primary heat exchanger.

Central heating output: 12kW

Efficiency

Print a handy summary about this product

                                                

Features and benefits

  • Best official boiler efficiency rating (SEDBUK band A)
  • 2 year guarantee with 10 year guarantee on primary heat exchanger (subject to terms and conditions)
  • Compact dimensions - can fit within kitchen cupboard
  • Built-in heating temperature control
  • Compatible with Greenskies solar panels
  • Low NOx and CO2 emissions - environmentally friendly
  • Multi-directional fluing for siting flexibility

  • For ease of installation, flow and return pipes can be plumbed in from above or below the boiler

  • Lift weight: just 22.6kg - the lightest boiler in its class

Technical data table

Technical data
Title Value
NOx classification with low NOx code plug (mg/kWh) 39
NOx classifications (mg/kWh) 44
Height (mm) 600mm
Width (mm) 390mm
Depth (mm) 270mm
Weight 22.6kg
Output to central heating and domestic hot water 4 - 12kW (13,648 - 40,944Btu/hr)
Solar compatible Yes
Maximum horizontal flue (100mm Ø) 4,600mm (inc. terminal)
Maximum vertical flue (100mm Ø) 6,400mm (inc. terminal)
Maximum horizontal flue (125mm Ø) 13,000mm (inc. terminal)
Maximum vertical flue (125mm Ø) 15,000mm (inc. terminal)
Gas connection 22mm compression
Heating flow and return connections 22mm compression
Maximum flow temperature 82ºC (180ºF)
Primary water content 1.1 litres
NOx class Class 5
Noise output level 39 dB(A)
SEDBUK value %/band - natural gas 90.1% / Band A
SEDBUK value %/band - LPG 91.4% / Band A

Literature

Product guides and brochures
Title/description Part number Order
Greenstar gas boiler brochure

A guide to our gas boilers and choosing the best boiler for your home.

8 716 109 642

download icon Download (1.24 Mb)

order icon Order a printed copy

Product guide for gas boilers and solar heating

Quick pocket-sized reference for trade professionals on gas boilers and solar water heating.

8 716 116 255

download icon Download (5.35 Mb)

order icon Order a printed copy

Product literature
Title/description Part number Order
Gas boiler wiring guide 6 720 646 965

download icon Download (18.11 Mb)

Installation and servicing instructions for Greenstar Ri (manufactured Aug 08 - Dec 10) 8 716 115 168

download icon Download (2.95 Mb)

order icon Order a printed copy

Installation and servicing instructions for Greenstar Ri (manufactured from Jan 11 onwards) 6 720 644 744

download icon Download (8.28 Mb)

order icon Order a printed copy

Installation and servicing instructions for Greenstar Ri (manufactured March 2005 - July 2008) 8 716 112 052

download icon Download (4.18 Mb)

order icon Order a printed copy

Product bulletin: new low NOx boilers, new Greenstar Si and i System controls Gas PB 01/2011

download icon Download (1.09 Mb)

Tech and spec for wall mounted gas regular boiler 8 716 115 774

download icon Download (4.14 Mb)

order icon Order a printed copy

User manual for Greenstar Ri (manufactured Aug 08 - Jan 11) 8 716 115 172

download icon Download (0.85 Mb)

order icon Order a printed copy

User manual for Greenstar Ri (manufactured from Dec 2010) 6 720 644 865

download icon Download (0.36 Mb)

order icon Order a printed copy

User manual for Ri (manufactured March 2005 to July 2008) 8 716 109 698

download icon Download (0.35 Mb)

order icon Order a printed copy

Accessory literature
Title/description Part number Order
Greenstar 12Ri and 15Ri LPG conversion kit 8 716 109 867

download icon Download (2.02 Mb)

order icon Order a printed copy

Greenstar low loss header bulletin L-loss PB 12/2011

download icon Download (0.68 Mb)

Ri syphon fitting instructions 8 718 683 176

download icon Download (0.41 Mb)

order icon Order a printed copy

Flue literature
Title/description Part number Order
60/100mm horizontal flue instruction manual 6 720 644 842

download icon Download (5.64 Mb)

order icon Order a printed copy

60/100mm Vertical flue kit instructions 6 720 611 739

download icon Download (0.41 Mb)

order icon Order a printed copy

80/125mm 45° flue duct kit instructions 6 720 641 098

download icon Download (0.18 Mb)

order icon Order a printed copy

80/125mm 90° flue duct kit instructions 6 720 641 097

download icon Download (0.18 Mb)

order icon Order a printed copy

80/125mm flue extension kit instructions 6 720 641 099

download icon Download (0.14 Mb)

order icon Order a printed copy

80/125mm horizontal flue instructions 6 720 611 436

download icon Download (0.31 Mb)

order icon Order a printed copy

Get Adobe Reader

PDF files can be read with
Adobe Acrobat Reader

Social media