Boiler location & clearances

Bathrooms

IMPORTANT:

Any switch or appliance control using mains electricity must not be able to be touched by a person using the bath or shower.

Electrical switches, fused spurs and socket outlets must not be situated in the bathroom.

A boiler fitted with a non-mechanical timer or with no timer can be installed in zone 2 or outside the shaded area.

A boiler with a mechanical timer or RF mechanical timer with a room thermostats must only be installed outside the shaded area.

Additional Residual Current Device (RCD) protection may be required.

Refer to IEE wiring regulations.

Image of Boiler clearances for combi boilers 1

Image of Boiler clearances for combi boilers 2