Can I put flue elbows straight on top of the boiler?
Elbows for offsetting can be fitted directly into the flue turret, or high level adapter on all our wall hung boiler variants. There is no requirement for running any straight flue length between them.
Please check our manual for total flue length allowance, as most extra 90 degree bends will result in either a 1500mm (Greenstar CDi Classic Range) or 2000mm (All other ranges) reduction and a 45 degree bend will lose 750mm (Greenstar CDi Classic Range) or 1000mm (All other ranges).
More All FAQs
- The MyWorcester App has now been retired and is no longer available, please download our new app.
- How many colours is the EasyControl available in?
- How are installers selected to complete FastTrack installation jobs?
- What happens if the customer doesn’t meet the FastTrack criteria?
- How do I give my engineers access?
- Top tips commissioning a Greenstar Danesmoor oil boiler
- Is an external air break required when a condensate pipe is terminated into a rainwater downspout?
- How do I re-route a condensate pipe to reduce the external run?
- Have you got more information on how to wire controls to your range of Greenstar gas boilers?
- How many immersion heaters do you have in your cylinders?