How do I re-route a condensate pipe to reduce the external run?
It is possible to terminate a condensate pipe into a rain water down pipe that terminates into the foul waste system. As with all externally-run condensate pipes, it is recommended to keep the external run to minimum and the pipe diameter to 32mm when exiting the property.
An air break must be installed between the appliance condensate outlet and the drainpipe connection. This needs to be external to the property to avoid flooding should the downpipe become blocked. Failure to include an external air break may result in severe damage to the appliance and may invalidate the warranty.
See here for more information
More All FAQs
- The MyWorcester App has now been retired and is no longer available, please download our new app.
- How many colours is the EasyControl available in?
- How are installers selected to complete FastTrack installation jobs?
- What happens if the customer doesn’t meet the FastTrack criteria?
- How do I give my engineers access?
- Top tips commissioning a Greenstar Danesmoor oil boiler
- Is an external air break required when a condensate pipe is terminated into a rainwater downspout?
- Have you got more information on how to wire controls to your range of Greenstar gas boilers?
- How many immersion heaters do you have in your cylinders?
- What are the kW outputs of the coils inside Worcester cylinders?