Greenstar 30CDi Classic System
Description
The Greenstar 30CDi Classic System boiler is our top performing system boiler. It’s suited to bigger properties with a larger heating requirement.
The boiler is compatible with a wide range of optional controls, offering you superb flexibility with your heating and hot water times and temperatures.
The Greenstar CDi Classic System boiler offers the ultimate in energy savings when combined with our new generation intelligent controls and our Greenskies solar water heating panels.
For further peace of mind, every boiler in Worcester’s Greenstar gas and LPG condensing boiler range has been awarded a Which? Best Buy accreditation.
5 year boiler guarantee until 30th June 2013 (terms and conditions apply). See promo page for details.
10 year guarantee on primary heat exchanger.
Central heating output: 30kW
Efficiency
This boiler is registered with the Energy Saving Trust.
This boiler is compatible with Greenskies solar panels
Features and benefits
A rated efficiency (SAP 2005 seasonal efficiency)
5 year boiler guarantee until 30th June 2013, terms and conditions apply (standard guarantee: 2 years)
10 year guarantee on primary heat exchanger
Both hot water and central heating temperatures can be controlled*
- Compatible with Greenskies solar water heating panels
Wall mounting frame with pipes behind - no exposed pipework
Vertical pre-piping kit
- Below boiler pipe cover
Earth bonding strip
Low NOx and CO2 emissions - environmentally friendly
- Digital and new generation intelligent controls are compatible*
*Provided optional integral diverter valve is fitted
Technical data table
| Technical data | |
|---|---|
| Title | Value |
| NOx classifications (mg/kWh) | 33.3 |
| Height (mm) | 760 (max) |
| Width (mm) | 440 |
| Depth (mm) | 360 (max) |
| Weight | 46.5kg |
| SEDBUK value %/band - LPG | 92.3% / Band A |
| SEDBUK value %/band - natural gas | 90.3% / Band A |
| Output to central heating | 7.7 - 30kW |
| Solar compatible | Yes |
| Maximum horizontal flue (100mm Ø) | 7,900 |
| Maximum vertical flue (100mm Ø) | 9,400 |
| Maximum horizontal flue (125mm Ø) | 18,500 |
| Maximum vertical flue (125mm Ø) | 18,500 |
| Gas connection | 22mm compression |
| Pressure relief valve | 15mm compression |
| Heating flow and return connections | 22mm compression |
| Condensate connection | 22mm plastic pipe |
| Flow & Return Pipes Supplied to Allow Pipes Behind Installation | Yes |
| Primary water content | 3.75L |
| NOx class | Class 5 |
| Wall mounting jig | Yes |
| Fault diagnostic display | Yes |
| Plug-in timers | Yes (optional) |
| Optimising room temperature controller | Yes (optional) |
| Intelligent controls | Yes (optional) |
| Ingress protection rating | X4D |
Literature
| Product guides and brochures | ||||
|---|---|---|---|---|
| Title/description | Part number | Order | ||
| Greenstar gas boiler brochure A guide to our gas boilers and choosing the best boiler for your home. |
8 716 109 642 | |||
| Product guide for gas boilers and solar heating Quick pocket-sized reference for trade professionals on gas boilers and solar water heating. |
8 716 116 255 | |||
| Product literature | ||||
|---|---|---|---|---|
| Title/description | Part number | Order | ||
| Gas boiler wiring guide | 6 720 646 965 | |||
| Greenstar CDi service booklet for engineers | 8 716 115 748 | |||
| Guide to re-setting the 'SE' code on Greenstar CDi boilers | 8 716 112 353 | |||
| Installation and servicing instructions for Greenstar CDi Classic System | 6 720 647 473 | |||
| Tech and spec for wall mounted gas system boilers | 8 716 115 775 | |||
| User manual for Greenstar CDi System | 6 720 612 454 | |||
| Accessory literature | ||||
|---|---|---|---|---|
| Title/description | Part number | Order | ||
| CondenseSure brochure | 8 716 116 559 | |||
| CondenseSure Siphon - Installation instructions | 6 720 803 103 | |||
| DT10RF Digistat (MK 2) instructions | 8 716 115 493 | |||
| DT10RF optimiser (MK 2) instructions | 8 716 115 494 | |||
| DT20 Twin Channel Digital Timer user instructions | 8 716 106 647 | |||
| DT20RF Digital RF thermostat with twin channel programmer (MK 2) instructions | 8 716 115 495 | |||
| FR10 instructions | 6 720 617 760 | |||
| FR110 instructions | 6 720 617 762 | |||
| FW100 instructions | 6 720 617 763 | |||
| FW100 Quick guide | 6 720 617 764 | |||
| Greenstar low loss header bulletin | L-loss PB 12/2011 | |||
| Integral diverter valve instruction manual | 6 720 612 476 | |||
| ISM1 instructions | 6 720 617 761 | |||
| Tech and spec for heating controls | 8 716 115 653 | |||
| Flue literature | ||||
|---|---|---|---|---|
| Title/description | Part number | Order | ||
| 60/100mm horizontal flue instruction manual | 6 720 644 842 | |||
| 60/100mm Vertical flue kit instructions | 6 720 611 739 | |||
| 80/125mm 45° flue duct kit instructions | 6 720 641 098 | |||
| 80/125mm 90° flue duct kit instructions | 6 720 641 097 | |||
| 80/125mm flue extension kit instructions | 6 720 641 099 | |||
| 80/125mm horizontal flue instructions | 6 720 611 436 | |||